造成KRDC系列多槽清洗机不加热不升温的因素

作者:admin来源:http://www.jnthcsb.com/时间:2022-07-09

KRDC系列多槽清洗机的加热功能可以有效提高清洗效率,一般加热功能只支持加热到80摄氏度。如果再高一点,对清洗效果影响不大,80度已经达到了少量液体的沸点。任何更高将达到大多数液体的沸点。如果您购买的设备有加热功能,但在使用过程中加热功能失效,具体是什么原因?
The heating function of KRDC series multi tank cleaning machine can effectively improve the cleaning efficiency. Generally, the heating function only supports heating to 80 ℃. If it is higher, it will have little impact on the cleaning effect. 80 degrees has reached the boiling point of a small amount of liquid. Any higher will reach the boiling point of most liquids. If the equipment you purchased has heating function, but the heating function fails during use, what is the specific reason?
1、加热膜与电路板的连接断开;
1. The heating film is disconnected from the circuit board;
2、设定温度低于实际温度;
2. The set temperature is lower than the actual temperature;
3、加热膜烧坏;
3. The heating film is burnt out;
4、控制面板温度设置模块无效。
4. The control panel temperature setting module is invalid.
超声波清洗设备
导致KRDC系列多槽清洗机不升温的因素有哪些?针对这些可能的原因,我们可以通过以下方式来判断和处理。
What are the factors that lead to the non heating of KRDC series multi tank cleaning machine? For these possible reasons, we can judge and deal with them in the following ways.
1、检查加热膜与电路板连接的电路是否断开。如果是这样,您可以自己连接并再次测试;
1. Check whether the circuit between the heating film and the circuit board is disconnected. If so, you can connect yourself and test again;
2.当您设定的温度低于液体的实际温度时,加热功能不开启。可以查看自己设定的温度,提高设定温度来测试加热功能是否正常开启。
2. When the temperature you set is lower than the actual temperature of the liquid, the heating function does not turn on. You can check your set temperature and increase it to test whether the heating function is normally turned on.
3、加热膜一般覆盖在清洗槽的外表面,可以观察是否烧坏。如果发热膜烧坏,需要联系超声波清洗设备厂家更换维修。
3. The heating film is generally covered on the outer surface of the cleaning tank, and you can observe whether it is burnt out. If the heating film is burnt out, contact the manufacturer of ultrasonic cleaning equipment for replacement and maintenance.
4、如果排除以上原因,很有可能是控制面板的问题。
4. If the above reasons are eliminated, it is likely to be the problem of the control panel.
以上就是今天为大家介绍的关于问题以及注意事项的全部内容,希望对大家能有所帮助,想要了解更多内容可以电话联系我们或者关注我们的网站www.jnthcsb.com,我们的工作人员会及时与您取得联系。
The above is all about the problems and precautions introduced to you today. I hope it can help you. If you want to know more, you can contact us by phone or follow our website www.jnthcsb COM, our staff will contact you in time.